 40 WATT MEDICAL POWER SUPPLIES
DESCRIPTION
The PM40AL series of compact, open PCB constructed, AC-DC switching power supplies are capable of delivering 40 watts of continuous output power. They operate at 85 to 264 VAC input voltage without the need of voltage selection. They are ideally suited for use in medical equipment, safety systems and monitoring equipment, not for patient contact.
PM40AL SERIES
(MDD)
F E ATU R E S
Low safety ground leakage current 100% burn-in W i d e i n p u t r a n g e 8 5 t o 2 6 4 VA C Input surge current protection Overvoltage protection Overcurrent protection Open PCB construction
I N P U T S P E C I F I C ATI O N S Input voltage Input frequency Input current Leakage current
85 to 264 VAC 47 to 63 Hz
S a f e t y St a n d a r d A p p ro v a ls UL 2601-1 CSA C22.2 No. 601.1 TUV EN60601-1
1.20Armsfor 115VAC
0.70Armsfor 230VAC 150uA max. @ 230VAC, 50Hz
90 uA max. @ 115VAC, 60Hz GENERAL SPECIFICATIONS OUTPUT SPECIFICATIONS
Output voltage/current Total output power Ripple and noise Overvoltage protection See rating chart 40 watts maximum 1 peak to peak maximum Provided on output #1 only; set at 112 - 132 of its nominal output voltage All outputs protected to short circuit conditions All outputs 0.04 / maximum Maximum excursion of 4 or better on all models, recovering to 1 of final value within 500us after a 25 step load change Switching frequency Efficiency 36KHz 5KHz 70 minimum on single output models with Vo 15V, 65% minimum on the others 10 msec minimum at 110VAC 0.5 maximum at full load
Hold-up time Line regulation Inrush current
Overcurrent protection Temperature coefficient Transient response
E N V I R O N M E N TA L S P E C I F I C ATI O N S Operating temperature Storage temperature Relative humidity Derating
0 to +70 -40 to +85 5to 95non-condensing Derate from 100 at +50 linearly to 50% at +70
15 amps @ 115VAC, or 30 amps @ 230VAC, at 25 cold start Withstand voltage 4000VAC from input to output 1500VAC from input to ground 500VAC from output to ground MTBF 600,000 hours minimum at full load at 25 ambient, calculated per MIL-HDBK-217F EMC Performance (EN60601-1-2: 2001) Class B conducted, class B radiated EN55011 Class B conducted, class B radiated FCC Class B conducted, class B radiated VCCI Harmonic distortion, class A and D EN61000-3-2 Line flicker EN61000-3-3 ESD, 8KV air and 6KV contact EN61000-4-2 Radiated immunity, 3V/m for 80~2500MHz EN61000-4-3 Fast transient/burst, 2KV EN61000-4-4 Surge, 1KV diff., 2KV com. EN61000-4-5 Conducted immunity, 3Vrms EN61000-4-6 Magnetic field immunity, 3A/m EN61000-4-8 Voltage dips, 30% reduction for 500ms, EN61000-4-11 60% reduction for 100ms and >95% reduction for 10ms
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 sales@trumpower.com www.TRUMPower.com
MEDICAL GRADE
OUTPUT VOLTAGE/CURRENT RATING CHART
(1)(2) Model PM40-10AL PM40-12AL PM40-13AL PM40-14AL PM40-18AL PM40-23AL PM40-24AL PM40-25AL PM40-30AL PM40-31AL PM40-32AL PM40-33AL PM40-39AL Notes: Vnom. 5V 12V 15V 24V 48V +5V +5V +5V +5V +5V +5V +5V +5V Output #1 Imin. Imax. 0A 8.0A 0A 0A 0A 0A 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A 0.5A 3.5A 3.0A 2.0A 0.9A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A 3.0A Tol. 2% 1% 1% 1% 1% 3% 3% 3% 3% 3% 3% 3% 3% +12V +15V +24V +12V +12V +15V +15V +24V Vnom. Output #2 Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) 0.2A 0.2A 0.1A 0.2A 0.2A 0.2A 0.2A 0.1A 2A 2A 1A 2A 2A 2A 2A 1A 5% 5% 5% 5% 5% 5% 5% 5% Tol.
PM40AL SERIES
Vnom. Output #3 Imin. Imax. (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) (N/A) -5V -12V -15V -12V -12V 0.05A 0.05A 0.05A 0.05A 0.05A 0.3A 0.3A 0.3A 0.3A 0.3A 10% 10% 10% 10% 10% Tol. Maximum Output Power 40W 40W 40W 40W 40W 40W 40W 40W 40W 40W 40W 40W 40W
(1) All multiple output models may be operated at no-load without damage. At no-load, output voltage tolerance increases to 10% (2) Safety agency approvals are for the above listed models in PCB format. To order a model with a metallic L-bracket or box, change suffix "AL" to "BL" for L-bracket format or to "CL" for enclosed format (mechanical details shown in page 7-1), e.g. PM40-14BL.
MECHANICAL SPECIFICATIONS
NOTES: 1. Dimensions shown in inch [mm] 2. Tolerance 0.02 [0.5] maximum 3. Input connector mates with Molex housing 09-50-3031 and Molex 2878 series crimp terminal. 4. Output connector mates with Molex housing 09-50-3061 and Molex 2878 series crimp terminal. 5. Weight: 230 grams (PCB format) 6. It's strongly recommended to connect the two "" marked mounting holes to system chassis through metallic stand-offs. This helps reduce greatly output noise.
PIN CHART PIN MODEL PM40-10AL PM40-13AL PM40-18AL PM40-23AL PM40-25AL PM40-30AL PM40-32AL PM40-39AL PM40-12AL PM40-14AL PM40-24AL PM40-31AL PM40-33AL
1 2 3 4 5 6
OUTPUT #1 OUTPUT #2 OUTPUT #2
OUTPUT #1 OUTPUT #1 OUTPUT #1
OUTPUT #1 OUTPUT #1 OUTPUT #1
RETURN COMMON RETURN COMMON RETURN
RETURN COMMON RETURN COMMON RETURN
RETURN N.C. OUTPUT #3
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Bldg. 13, Santa Clara, California 95054, USA Phone: 408-988-6616 sales@trumpower.com www.TRUMPower.com


▲Up To Search▲   

 
Price & Availability of PM40-25AL

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X